DAMMAM · KINGDOM OF SAUDI ARABIA sales@plssa.com

Substation load testIllustration

Best equipment · Kingdom of Saudi Arabia

Your trusted partner for load testing solutions

Precision load testing, loadbank rental and generator maintenance for the Kingdom's power infrastructure — from data centres in Riyadh to industrial plants across the Eastern Province.

Load bank models
17
Reference projects
12
Cities served
6
Largest generator test
5 MW
  • AVR & Governor Response Checks
  • Prove Power Management System
  • 100% Generator Load Test
  • Prove Protection Schemes
  • Synchronizing Checks
  • Full System Integration Load Test

What we do

Six services. One accountable team.

From load bank rental to battery and data centre testing — with operators, cabling and full documentation every time.

All services →
Fleet of grey load banks lined up in an equipment yard (illustration)
01 / 06Illustration

Rental · testing

Loadbank Rentals

Our load banks provide comprehensive, flexible and cost-effective solutions for testing critical power systems. With a wide range of capacities and types, along with expert support and documentation, they ensure power systems are reliable, safe and ready to handle the demands placed on them.

  • Resistive & reactive units — single or multiple
  • AC 100–10,000 kW and DC 12–600 VDC
  • Mobilised with operators and cabling
  • Full test documentation on completion
Engineers insulation-testing cables at a power transformer (illustration)
02 / 06Illustration

Supply · connection · testing

Transformer & Power Cables

Supply, connection and testing of transformers and MV & LV power cables, sized to your site load profile and commissioning programme. Every connection is verified before energisation and recorded in the test pack.

  • Step-up and step-down transformers, 480 V to 33 kV
  • MV & LV flexible power cables
  • MV termination by skilled technicians
  • Hipot and Megger insulation testing
Engineer load testing a containerised generator at dusk (illustration)
03 / 06Illustration

Commissioning · validation

Comprehensive Generator Testing

Staged load runs up to 100% of rated capacity, with AVR and governor response, protection schemes, synchronising and load sharing all verified under real load. Witnessed testing with a documented report on completion.

  • Staged load runs to 100% of rated capacity
  • AVR and governor response checks
  • Protection, synchronising and load sharing proven
  • Witnessed test with a documented report
Technician servicing a diesel generator engine (illustration)
04 / 06Illustration

Annual packages

Generator Maintenance

Annual maintenance packages designed to keep your equipment operating at peak performance — minimising downtime and maximising efficiency across your estate, with scheduled service visits and priority emergency response.

  • Scheduled service visits
  • Regular inspections
  • Preventive maintenance
  • Expert servicing by PLS technicians
Engineer discharge-testing a UPS battery bank (illustration)
05 / 06Illustration

Know your real back-up time.

Battery & UPS testing

Controlled discharge tests with our DC load banks verify the actual capacity and autonomy of UPS and battery systems — so weak strings are found before an outage, not during one.

  • Controlled discharge with DC load banks, 12–600 VDC
  • Actual capacity and autonomy verified
  • Weak strings found before an outage
  • UPS and battery systems tested in service
Portable load banks in a data centre aisle during commissioning (illustration)
06 / 06Illustration

Prove power and cooling before go-live.

Data centre testing

Load banks simulate the IT load to commission generators, UPS, distribution and thermal systems — from single systems to full integration load tests.

  • Load banks simulate the IT load
  • Generators, UPS, distribution and thermal systems
  • Single systems to full integration tests
  • 7 kW rack load banks simulate server racks
PLS engineer in front of containerised load banks at the Sahayeb data centres, Dammam

17load bank models in service

Khalidiyah, Dammam

About us

A Saudi load testing specialist — equipment and engineers in one team.

Power Line Services is a Dammam-based load testing company. We rent load banks, transformers and power cables, and test generators, UPS and battery systems for critical sites across Saudi Arabia.

  • From Dammam, Kingdom-wideProjects in Dammam, Jubail, Riyadh, Makkah, Buraydah and Ras Al-Khair
  • AC and DC100 kW – 10 MW · 12 – 600 VDC
  • Fully supportedOperators, cabling and full documentation with every test
  1. 01Engineering
  2. 02Commissioning
  3. 03Operational support

Our vision

To be the global leader in power system testing and optimisation.

Our mission

Cutting-edge load testing and end-to-end services for peak performance and lower risk.

Our values

  • Reliability redefined
  • Innovation delivered
  • Customer first
Read our full vision and mission

Industries we serve

Built for power that can't be allowed to fail.

Our load banks test mission-critical power systems — from routine commissioning to full emergency power validation.

01

Data centres

Commissioning and routine validation of generators, UPS and battery systems before they carry live load.

What we test

  • Generators
  • UPS
  • Battery systems
  • Cooling
Discuss your site
02

Healthcare facilities

Proving emergency power so critical systems stay on when the grid does not.

What we test

  • Emergency generators
  • UPS
  • Protection schemes
Discuss your site
03

Industrial plants

Load testing generators, synchronising panels and distribution ahead of start-up.

What we test

  • Generators
  • Synchronising panels
  • Distribution
Discuss your site
04

Utility infrastructure

Transformers, MV cable termination and insulation testing for dependable distribution.

What we test

  • Transformers
  • MV termination
  • Hipot & Megger
Discuss your site

Why choose us

From load to legacy.

Reliability isn't an option — it's a necessity.

PLS load banks loaded on a truck for mobilisation

Power testing isn’t just about performance — it’s about reliability when it matters most.

01

Available at short notice

Rental equipment with prompt delivery and professional installation, on your project timeline.

02

Test before commissioning

Prove systems before handover and reduce the risk of contract penalties for non-performance.

03

Optimised capital expenditure

Rent instead of buy — no large upfront payment or interest cost on equipment.

04

Sales & engineering support

A skilled team that helps you identify the right load testing solution for your requirements.

Key features of our load banks

  • Portability
  • Flexibility
  • Fast, reliable service
  • Comprehensive testing
  • Expert support
  • Cost-effective
  • Wide applications
  • Safety & reliability

Ready to prove your system? Tell us what you need to test.

Request a load test +966 55 786 4095

Load bank range

The right equipment for every rating.

Accurate, reliable and efficient testing equipment — available as single or multiple units.

View the fleet →

AC Load Banks

100 kW – 10,000 kW

Resistive and reactive configurations, available as single or multiple units for any testing requirement.

DC Load Banks

12 VDC – 600 VDC

Engineered to cover a broad spectrum of DC power systems and battery discharge regimes.

Transformers

480 / 600 V · 4.16 / 13.8 / 33 kV

Step-up and step-down units specified to your voltage, climate and system requirements — every transformer is unique.

Power Cables

MV & LV flexible

MV cable termination by qualified technicians, with Hipot and Megger testing before energisation.

PLS load bank fleet on display, from portable cased units to containerised banksPLS load bank fleet · Dammam

How we work

From enquiry to a tested, documented system.

  1. Step 01

    Scope

    Share your system, ratings and schedule. Our engineers identify the right load bank solution.

    You getA recommended load bank solution

  2. Step 02

    Mobilise

    Equipment delivered at short notice and professionally installed on site.

    You getEquipment delivered and installed on site

  3. Step 03

    Test

    Staged load testing — from AVR and governor response to full system integration.

    You getStaged load test up to full integration

  4. Step 04

    Document

    Results recorded and handed over, with expert support and documentation.

    You getRecorded results and full documentation

Start with step 01 — share your system and schedule.

Start your request +966 55 786 4095

Scope of work

What do you need to load test?

From generation to critical power — we test the whole system under real load.

PLS generator yard ready for load testing

Generation

4
  • Turbine generators
  • Diesel generators
  • DC generators
  • Power supplies
Electrical distribution panel with breakers

Distribution

2
  • Electrical distribution panels
  • Synchronizing panels
PLS battery discharging testers

Critical power

4
  • UPS systems
  • Battery discharge
  • Data centre power
  • Thermal systems

Don’t see your equipment? Ask our engineers

PLS load bank on site at night

Why load test?

What a load test proves

  1. 01AVR & Governor Response Checks
  2. 02Prove Power Management System
  3. 03100% Generator Load Test
  4. 04Prove Protection Schemes
  5. 05Synchronizing Checks
  6. 06Prove Load-Sharing Equipment
  7. 07Full System Integration Load Test
Plan my load test

Selected projects

Proven on the Kingdom’s critical sites.

From Aramco Stadium to the Sahayeb data centres — 12 reference projects testing generators, UPS and batteries in 6 cities.

All 12 projects →

Clients and sites we’ve worked on 12

Request a quote

Tell us what you need to test.

Tell us about the equipment, site and schedule — our engineers will recommend the right load bank and test plan.

  1. 01
    Scope

    Share your system, ratings and schedule. Our engineers identify the right load bank solution.

  2. 02
    Mobilise

    Equipment delivered at short notice and professionally installed on site.

  3. 03
    Test

    Staged load testing — from AVR and governor response to full system integration.

  4. 04
    Document

    Results recorded and handed over, with expert support and documentation.

1Your project

WHAT DO YOU NEED?

2Your details

Goes straight to our sales engineers — we reply within one working day.

01What capacity of load banks do you supply?

AC load banks from 100 kW to 10,000 kW in resistive and reactive configurations, as single or multiple units, and DC load banks from 12 VDC to 600 VDC.

02Do you supply transformers and power cables?

Yes. Step-up and step-down transformers at 480 V, 600 V, 4.16 kV, 13.8 kV and 33 kV, and MV & LV flexible power cables with MV termination, Hipot and Megger testing.

03Do you provide operators and cabling?

Yes. Load banks are mobilised with operators, cabling and full test documentation.

04Why load test before commissioning?

Testing proves generators, UPS and protection systems under real load before handover, which significantly reduces the risk of contract penalties for non-performance.

05Do you test UPS and battery systems?

Yes. Controlled discharge tests with our DC load banks (12–600 VDC) verify the actual capacity and autonomy of UPS and battery systems — so weak strings are found before an outage, not during one.

06Can you commission data centre power and cooling?

Yes. Load banks simulate the IT load to commission generators, UPS, distribution and thermal systems — from single systems to full integration load tests.

07What documentation do we receive?

Results are recorded and handed over with full test documentation. Generator load tests are witnessed, with a documented report on completion.

08Can you supply equipment at short notice?

Yes. Rental equipment is available at short notice, with prompt delivery and professional installation to meet your project timeline.

09Do you offer generator maintenance?

Yes. Annual maintenance packages include regular inspections, preventive maintenance and expert servicing to reduce downtime and repair costs.

10Where are you based?

Our office is in Khalidiyah, Dammam. Call +966 55 786 4095 or email sales@plssa.com to discuss your site and schedule.

11What information do you need to quote?

Share your system, ratings and schedule — our engineers identify the right load bank solution. The quote form on this page covers everything we need.

12Why rent instead of buying a load bank?

Renting optimises capital expenditure — no large upfront payment and no interest cost on equipment — while you still test with the right capacity for each project.

Your trusted partner for load testing solutions in the Kingdom.